Abstract
The Tank Farms Final Safety Analysis (FSAR) assumes that a ventilation stack Continuous Air Monitor (CAM) interlock system detects high radiation in the exhaust stream and shuts off the associated ventilation system within 10 minutes of a High-Efficiency Particulate Air (HEPA) filter system failure (CHG, 2002). Previous analysis of the as-built CAM system on the AW Farm Primary Exhauster (stack 296-A-27) showed that this system potentially required significantly longer than 10 minutes to detect a HEPA filter failure and initiate shutdown of the ventilation system (Short, 2002). The purpose of this report is to determine the CAM interlock system response time for a proposed upgrade of the 296-A-27 CAM system. The approach to be used in this analysis is essentially the same as used in RPP-10799, Rev. 0 (Short, 2002), which is to conservatively estimate the time required by the proposed upgraded CAM sampling/monitoring system to detect a FSAR-defined HEPA filter failure and automatically shutdown the exhaust fan. For the HEPA filter failure over-temperature accident scenario in the FSAR, the upgraded CAM system on the AW Farm Primary Exhauster will require significantly less than 10 minutes to detect a HEPA filter failure, actuate the CAM Interlock, and shutdown the exhaustermore » fan. Therefore, the analyzed system is adequate to meet the operability requirements specified in the FSAR and the Tank Farms Technical Safety Requirements (CHG, 2001; CHG, 2002).« less