A 50-150 kWth pilot solar rig comprising the key equipments of a real plant and that uses silicon carbide Dense Particles Suspension as the heat transfer fluid has been tested at the 1 MW solar furnace at Odeillo-Font Romeu, France. The tests were carried out under large ranges of operating parameters and controlling the mass flow rate when higher temperature was required and when changes on DNI (direct normal irradiation) occurred. This paper presents experimental results on particle outlet temperature, dynamic response of the system to solid mass flow rate and solar power variations, and receiver thermal efficiency (η). Mean and maximum particles’ temperature up to 585°C and 720°C respectively was reached. The receiver thermal efficiency was measured in the range 50-90%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.