Abstract

The online temperature detections of fiber along the spinning line should be the important means for the precise controlling of fiber higher order structures as well as fiber-final performance. In this paper, a method of measurement fiber temperature has been introduced which mainly use the instrument of monochromatic infrared thermometer to measure fiber temperature in the melt-spinning processes. Due to the probe field of view of monochromatic infrared thermometer being much larger than the fiber diameter, monochrome infrared thermometers can't be used to measure temperature of fibers directly, the measurement results is an average between the fiber and backgrounds, which can't be used to indicate the temperature of fibers directly and have to calibrated. The calibrated results of monochromatic infrared thermometer are compared to the measurement results of infrared thermography. It has been found that the on-line measurement with infrared thermometer could promise high-speed and highly reliable temperature testing for the fibers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call