Abstract

This paper presents a feasibility study on a pre-flooded cavity strategy for cooling molten corium in OPR1000 nuclear power plants. The characteristics of debris beds formed in the pre-flooded reactor cavity are assumed to be the same as COOLOCE-8 BED, STXY BED, and POMECO BED-5. We conducted one-dimensional safety analysis on the coolability of the debris beds and the integrity of the containment during ex-vessel cooling. If the debris bed is uniformly formed throughout the reactor cavity, the integrity of the containment can be maintained. However, if the debris bed is formed only beneath the reactor vessel narrowly, the integrity of the containment structure cannot be maintained. Therefore, in order to assess the adequacy of the pre-flooded cavity strategy for ex-vessel cooling in OPR1000, the spreadability of fragmented particles and the possible debris bed shapes are needed to be studied thoroughly.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.