Abstract
In this paper we present the use of static temperature measurements as process variation observable. Contrary to previously published thermal testing methods, the proposed methodology does not need an excitation signal, thus reducing test cost and improving built-in capabilities of thermal monitoring. The feasibility of the technique and a complete test methodology is presented using a narrowband LNA as example. Finally, a complete electro-thermal co-simulation test bench between the LNA and a differential temperature sensor embedded in the same silicon die is presented in order to validate the results. Results prove that RF figures of merit can be extracted from DC temperature measurements done without loading or exciting the RF circuit under test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.