Abstract

An analysis of an anomaly in the subcooled critical flow model in the RELAP5/MOD3 computer code is presented. Specifically, the code produces a discontinuity in going from unchoked subcooled liquid flow (i.e., subsonic flow) to subcooled choked flow (i.e., sonic flow). The same anomaly has been reported elsewhere. The root cause for this anomaly has been analyzed, and it is found that the user-supplied junction loss coefficient and discharge coefficient play an important role in the occurrence of this anomaly. The analysis is verified by assessment against a test problem simulating single-phase liquid flow through a convergent nozzle with a fixed upstream pressure and a varying downstream pressure. A corrective measure to eliminate the discontinuity is suggested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.