Abstract
Abstract Elucidation of the internal structure of fault zones is paramount for understanding their mechanical, seismological and hydraulic properties. In order to observe representative brittle fault zone structures, it is preferable that the fault be passively exhumed from seismogenic depths and the exposure must be in arid or semi-arid environments where the fragile rocks are not subject to extensive weathering. Field observations of two such faults are used to constrain their likely mechanical properties. One fault is the Carboneras fault in southeastern Spain, where the predominant country rocks are phyllosilicate-rich lithologies, and the other is part of the Atacama fault system in northern Chile, where faults pass through crystalline rocks of acidic to intermediate composition. The Carboneras fault is a left lateral fault with several tens of kilometres offset exhumed from approximately 4 km depth, and displays multiple strands of clay-bearing fault gouge, each several metres wide, that contain variably fractured lenses of protolithic mica schists. The strain is evenly distributed across the gouge layers, in accordance with the measured laboratory mechanical behaviour which shows predominantly strain hardening characteristics. The overall width of the fault zone is several hundred metres. Additionally, there are blocks of dolomitic material that are contained within the fault zones that show extremely localized deformation in the form of faults several centimetres wide. These are typically arranged at an angle of c . 20° to the overall fault plane. These differing types of fault rock products allow for the possibility of ‘mixed mode’ seismicity, with fault creep occurring along the strands of velocity strengthening clay-rich gouge, punctuated by small seismic events that nucleate on the velocity weakening localized faults within the dolomite blocks. The Caleta Coloso fault in northern Chile has a left-lateral offset of at least 5 km and was exhumed from 5–10 km depth. The fault core is represented by a 200–300 m wide zone of hydrothermally altered protocataclasite and ultracataclasite. This is surrounded by a zone of micro and macro-fractures on the order of 150 m thick. The fault core shows a heterogeneous distribution of strain, with alternate layers of ultracataclasite and lower strain material. The strain-weakening behaviour of crystalline rocks might be expected to produce highly localized zones of deformation, and thus the wide core zone must be a result of additional process such as precipitation strengthening or geometric irregularities along the fault plane.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.