Abstract

The reduction in visibility in x-ray grating interferometry based on the Talbot effect is formulated by the autocorrelation function of spatial fluctuations of a wavefront due to unresolved micron-size structures in samples. The experimental results for microspheres and melamine sponge were successfully explained by this formula with three parameters characterizing the wavefront fluctuations: variance, correlation length, and the Hurst exponent. The ultra-small-angle x-ray scattering of these samples was measured, and the scattering profiles were consistent with the formulation. Furthermore, we discuss the relation between the three parameters and the features of the micron-sized structures. The visibility-reduction contrast observed by x-ray grating interferometry can thus be understood in relation to the structural parameters of the microstructures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.