Abstract

In a recent paper, 1 it was shown that the profile inferred from differential capacitance measurement 2–5 of semiconductor junctions is not that of the impurity atom distribution but, instead, that of the majority carrier distribution. For this reason, conventional differential capacitance measurements can be used to evaluate the impurity atom distribution only in charge neutral semiconductor material (where the majority carrier density equals the density of ionized impurity atoms). This requirement of charge neutrality limits the applicability of this measurement technique to semiconductor material containing a minimum impurity atom density of about 10 16 atoms/cm 3 .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.