Abstract

In a recent paper, it was shown that (i) any reciprocal system with a proper transfer function possesses a signature-symmetric realization in which each state has either even or odd parity; and (ii) any reciprocal and passive behavior can be realized as the driving-point behavior of an electric network comprising resistors, inductors, capacitors and transformers. These results extended classical results to include uncontrollable systems. In this paper, we establish new lower bounds on the number of states with even parity (capacitors) and odd parity (inductors) for reciprocal systems that need not be controllable.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call