Abstract
The interharmonic generation process is addressed with reference to high power adjustable speed drives based on double stage conversion systems using line commutated or pulse width modulated inverters. Reference is made to ideal supply conditions. Formulas to forecast the interharmonic frequencies due to the interaction between the rectifier and the inverter are developed and a proper symbolism is proposed to recognize the interharmonic origins. Comprehensive analyses are performed for both the considered adjustable speed drives in a wide range of output frequencies and with reference to supply system side, output side, and dc link.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.