Abstract

The SORGENTINA-RF project aims to develop a 14 MeV fusion neutron source to produce medical radioisotopes with special focus on ^{99}Mo. The facility is based on a positive ion source with an acceleration stage to produce a deuterium (D^{+}) and tritium (T^{+}) ion beam that, impacting on a titanium-coated rotating target, allows fusion reactions to take place. Maximizing the neutron production rate is one of the main issues to be addressed in the project and the optimization of some key parameters of the ion beam is of paramount importance in this regard. In this study, a methodology is discussed to reach a definition of the beam characteristics for an effective and sustainable operation of the plant. The most convenient layout that has been found out is based on a single ion source fed by a deuterium and tritium gas mixture. Eventually, a series of considerations about the operation of the ion source and fuel cycle have been drawn.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.