Abstract

We have made an analysis of the conditions necessary for the successful use of the weak-beam technique for identifying and characterizing small point-defect clusters in ion-irradiated copper. The visibility of small defects was found to depend only weakly on the magnitude of the beam-convergence. In general, the image sizes of small clusters were found to be most sensitive to the magnitude of Sa with the image sizes of some individual defects changing by large amounts with changes as small as 0.025 nm{sup {minus}1}. The most reliable information on the true defect size is likely to be obtained by taking a series of 5-9 micrographs with a systematic variation of deviation parameter from 0.2-0.3 nm{sup {minus}1}. This procedure allows size information to be obtained down to a resolution limit of about 0.5 nm for defects situated throughout a foil thickness of 60 nm. The technique has been applied to the determination of changes in the sizes of small defects produced by a low-temperature in-situ irradiation and annealing experiment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.