Abstract
BackgroundThe application of machine learning to cardiac auscultation has the potential to improve the accuracy and efficiency of both routine and point-of-care screenings. The use of convolutional neural networks (CNN) on heart sound spectrograms in particular has defined state-of-the-art performance. However, the relative paucity of patient data remains a significant barrier to creating models that can adapt to a wide range of potential variability. To that end, we examined a CNN model’s performance on automated heart sound classification, before and after various forms of data augmentation, and aimed to identify the most optimal augmentation methods for cardiac spectrogram analysis.ResultsWe built a standard CNN model to classify cardiac sound recordings as either normal or abnormal. The baseline control model achieved a PR AUC of 0.763 ± 0.047. Among the single data augmentation techniques explored, horizontal flipping of the spectrogram image improved the model performance the most, with a PR AUC of 0.819 ± 0.044. Principal component analysis color augmentation (PCA) and perturbations of saturation-value (SV) of the hue-saturation-value (HSV) color scale achieved a PR AUC of 0.779 ± 045 and 0.784 ± 0.037, respectively. Time and frequency masking resulted in a PR AUC of 0.772 ± 0.050. Pitch shifting, time stretching and compressing, noise injection, vertical flipping, and applying random color filters negatively impacted model performance. Concatenating the best performing data augmentation technique (horizontal flip) with PCA and SV perturbations improved model performance.ConclusionData augmentation can improve classification accuracy by expanding and diversifying the dataset, which protects against overfitting to random variance. However, data augmentation is necessarily domain specific. For example, methods like noise injection have found success in other areas of automated sound classification, but in the context of cardiac sound analysis, noise injection can mimic the presence of murmurs and worsen model performance. Thus, care should be taken to ensure clinically appropriate forms of data augmentation to avoid negatively impacting model performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.