Abstract
On-orbit data are used to examine the performance of the Hubble Space Telescope optical control system. The precision, relative accuracy, and absolute accuracy of the off-axis Wavefront-Sensor measurements are evaluated and compared with design requirements. The internal stability of the sensors is better than 0.006 microm rms over five years, including launch. Random errors are estimated to be within 0.01 microm rms. Systematic errors are present in the estimates of focus, spherical, and coma aberrations, but none has been identified for astigmatism. Primary-mirror spherical aberration is believed to be the probable cause of all subspecification performances.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.