ABSTRACTTo investigate the applicability of the pulsed neutron source method using a pulsed spallation neutron source for an on-line subcriticality monitoring system of an accelerator-driven system, a subcritical experiment is conducted using the Kyoto University Critical Assembly in combination with the fixed-field alternating gradient accelerator. Reactivity values obtained from different traditional techniques, the area-ratio method and the α-fitting method, are discussed with respect to the applicability to on-line subcriticality monitoring. The results show that the area-ratio method robustly and accurately monitors subcriticality in shallow subcritical states with negative reactivity of up to a few dollars; however, this method faces problems with temporal fluctuations, spatial dispersion, and sensitivity to the proton-beam current with increasing depth of subcriticality. On the other hand, it is shown that the α-fitting method alleviates such problems in deep subcritical states. Moreover, a proposed fitting technique using the maximum-likelihood estimation method based on the Poisson distribution is robust enough to be applicable to on-line subcriticality monitoring for negative reactivity levels of up to roughly nine dollars.