We propose an original method to recover the whole thermal field of a heated object on a furnace from a few measurement points. The radiant thermal source is first identified via a low order reduced model based on AROMM (Amalgam Reduced Order Modal Model) method. From this identified temperature, the thermal field is then recovered by direct simulation using a reduced model of higher order which leads to a better precision. This process is applied to a complex titanium object heated by two radiant panels placed in the furnace. From two measurement points, the temperature of the heated object is recovered on-line, with a mean error below 3K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.