Abstract

We propose an original method to recover from a few measurement points the integrity of the temperature field of a furnace heated by a radiant thermal source. The radiant thermal source is first identified via a low order reduced model based on based on AROMM (Amalgam Reduced Order Modal Model) method which preserves the integrity of the geometry. The minimization is performed via a trust-region reflective least squares algorithm implemented in MATLAB “lsqcurvefit” function. From that identified heat flux, the integrity of the thermal field is then recovered by direct simulation thanks to a reduced model of higher rank to have a better precision. The treated application is a complex titanium piece heated by two radiant panels placed in a furnace. With four measuring points, the temperature of the whole thermal scene is retrieved at all times with an average error around 1 K on the studied object.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.