Abstract

The purpose of the article is to analyze the damage rate of overhead power transmission lines (OPL) in medium-voltage electrical distribution networks of the Irkutsk region. The established International Indices that determine the level of reliability of the functioning of electric networks are considered, and information on the compliance of the condition of electric networks in Russia with these indices is analyzed. Analytical information on the damage rate of elements of these networks and their causes in Europe, America, and Russia is presented. The emphasis is placed on the fact that the most common damage is characteristic of overhead power lines, especially 6–10 kV lines. As an object of research, two branches of the Irkutsk electric grid company (IEC) were taken, one of which provides electricity to rural consumers, the other — mainly to consumers residing in the territory of the city Irkutsk. The characteristics of these electric networks, their territorial location and basic technical data are presented. To conduct analytical monitoring of the level of reliability of overhead power transmission lines, logs of disconnection of the Eastern and Southern electric networks of the IEC over a long-term period were used. On the basis of this information, tables of failures and their consequences in the studied electrical networks were compiled for monthly average data over the period under examination for various causes of damage. To plot time diagrams of the parameters under examination, computer programs were compiled in the Matlab system, the use of which made it possible to obtain visualization of changes in failures for various reasons for the electrical networks under consideration. The information on the time of power supply interruptions in these networks, as well as the amount of electricity underutilized by consumers during these interruptions and its cost are analyzed. It is shown that in the electric networks under consideration, most of the power failures are related to the territorial dispersion of these networks, and the low level of equipment controls and insufficient qualification of operating personnel, as evidenced by the significant number of failures for unknown reasons. Besides, a significant part of the failures is due to damage to the overhead line wires, switching equipment and the effect of wind load. Recommendations for improving the condition of power transmission lines and a number of measures aimed at improving the level of reliability of power supply are presented.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call