Abstract

The aim of this work is the design of an algorithm for on-board determination of the actual capacity of a lithium iron phosphate (LFP) cathode-based lithium-ion battery for electric vehicle applications. The presented approach is based on the detection of the predominant aging mechanisms (in terms of loss of lithium and loss of active material in both electrodes) by determining the single electrode voltage curves. The information related to the characteristic length and position of the voltage plateaus, which can be gathered during battery operation, can be used to obtain the actual aging state of the cells. The length of the plateaus depends on the respective position that the voltage curves of the single electrodes have in relation to each other. Relating the change of the plateau characteristics to the possible aging mechanisms allows the determination of the actual battery aging state in terms of total cell capacity. The work presents a possible implementation of an algorithm for capacity determination based on the described methodology. The algorithm is validated with various differently aged LFP cells. Furthermore, the work discusses the ability of the method to detect the actual battery capacity if the characteristics of only part of the quasi-OCV (open circuit voltage) curve are detected. Achieved accuracy and existing limitations are described and discussed in detail.