Abstract

With any rotating machinery as lube oil leaves bearings, a certain amount of lube oil is aerated, resulting in the formation of a mist of very small size (less than 1 μm diameter) particles. If oil mist elimination system is not sized and designed properly, it could cause various issues such as increased operation and maintenance cost, re-entry of oily air into adjacent gas turbine units, fouling of surrounding atmosphere, and creation of oil slick on concrete floors, besides impacting environmental requirements and safety hazards. This paper presents a case study involving GE 7EA gas turbines operating at the Watson Cogeneration Plant and discusses issues with the existing oil mist elimination system and steps taken for a successful replacement of the original equipment manufacturer (OEM) supplied mist elimination system with non-OEM designed and fabricated mist elimination system. The replaced system demonstrated significantly higher life expectancy than it was designed for.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.