Abstract

To describe previously unreported ocular injuries from stainless-steel wire or suture used for facial skeletal or soft-tissue repair. Three patients who underwent orbital reconstruction (n = 2) or ptosis repair with excision of the orbiculus oculi (n = 1) were referred with signs and symptoms of ocular injury. Removal of the wires and sutures. Treatment resolved discomfort and irritation and diminished ocular motility, iritis, and bullous keratopathy but did not improve diminished vision in one of the patients. Occult ocular injury from misdirected or migrating stainless-steel wire should be considered in any case of ocular injury following orbital fracture or reconstructive repair when other disease processes are readily excluded. In these three cases, stainless-steel wire or suture impinged against or impaled the globe. The use of rigid plate fixation for orbital reconstruction or otherwise placing all stainless-steel wires and sutures outside the confines of the orbit would avoid such ocular injury.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.