During the study of various problems related with centrifugal pumps, it would be extremely convenient to have a head characteristic (head-capacity curve) approximated by any mathematical function. In so doing, in the field of small pump output flow experiments show that its characteristic is linear. In order to verify that this characteristic is truly linear, a mathematical experiment was carried out using the methods of hydrodynamic modeling and its approximation was carried out using the least square method and the maximum deviation from it was calculated.