Abstract

The features of the latent track in polycarbonate can be analysed by measuring the diffusion constant under ultra high vacuum conditions. Stacks of 30 μm Makrofol KG foils were irradiated with uranium ions of 11.4 MeV/u at the GSI Darmstadt, Germany. We used different fluences from 3·10 10 to 5·10 11 ions/cm 2. The diffusion constant was determined by the time-lag-method [1]. A quadrupole mass filter was used to observe the diffusion of the gas. We measured the diffusion of argon through different foils of each stack at room temperature. In all cases also unirradiated foils were measured. The dependence of the permeability and the diffusion constant on the ion fluence and the energy loss of the ions will be given and indications on the size of latent ion tracks concerning gas diffusion will be discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call