Abstract

Abstract This study analyzes the spatial and temporal distribution characteristics of the in situ aircraft observations in the middle and higher troposphere in 2019. These aircraft observations are mainly distributed in China, and relatively evenly recorded between 0000 and 1500 UTC in time and 6 and 10 km in height. Based on the 3395 stronger clear-air turbulence (CAT) events and 4038 weaker CAT events selected from the observations in the study region (15°–55°N, 70°–140°E), the performances of 24 CAT diagnostics calculated from the ERA5 data are evaluated. Results show that the diagnostics connected with vertical wind shear (i.e., version 1 of the North Carolina State University index, negative Richardson number, variant 3 and variant 1 of Ellrod’s turbulence index) have the best performances. However, the performances vary greatly from season to season, and overall performances are the best in winter and worst in summer. The annual and seasonal best thresholds for these diagnostics are also listed in this study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.