Abstract

Objective The aim was to compare muscle fiber diameters obtained from standard muscle biopsy and from computer simulations based on recorded motor unit potentials (MUPs). Methods Electromyography (EMG) and muscle biopsy were performed in 14 patients with a suspicion of a neuromuscular disorder. Histograms of the simulated muscle fiber diameters (SMFDs) were compared with those from the biopsy. Results The values of the SMFDs were similar to those in the muscle biopsy for the same patient (p = 0.05) in all 14 cases. Conclusions Comprehensive evaluation of EMG and biopsy findings supported by computer simulations may help resolve the discrepancy between the assessment of muscle by EMG and biopsy by explaining different results obtained with these two methods: Evaluation of the SMFDs that are comparable to biopsy findings extends the amount of information available from EMG.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.