Abstract

Background:Studies on nurse competence on alarm management are a few and tend to be focused on limited skills. In response to Phase II of implementing the National Patient Safety Goal on clinical alarm systems safety, this study assessed nurses’ perceived competence on physiologic monitors use in intensive care units (ICUs) and developed and validated a tool for this purpose.Methods:This descriptive study took place in a Magnet hospital in a Southwestern state of the U.S. A Nurse Competence on Philips Physiologic Monitors Use Survey was created and went through validation by 13 expert ICU nurses. The survey included 5 subscales with 59 rated items and two open-ended questions. Items on the first 4 subscales reflect most common tasks nurses perform using physiologic monitors. Items on the fifth subscale (advanced functions) reflect rarely used skills and were included to understand the scope of utilizing advanced physiologic monitors’ features. Thirty nurses from 4 adult ICUs were invited to respond to the survey.Results:Thirty nurses (100%) responded to the survey. The majority of nurses were from Neuro (47%) and Surgical Trauma (37%) ICUs. The data supported the high reliability and construct validity of the survey. At least one (3%) to 8 nurses (27%) reported lack of confidence on each item on the survey. On the first four subscales, 3% - 40% of the nurses reported they had never heard of or used 27 features/functions on the monitors. No relationships were found between subscales’ scores and demographic characteristics (p > .05). Nurses asked for training on navigating the central-station monitor and troubleshooting alarms, and the use of unit-specific super users to tailor training to users’ needs.Conclusion:This is the first study to create and test a list of competencies for physiologic monitors use. Rigorous, periodic and individualized training is essential for safe and appropriate use of physiologic monitors and to decrease alarm fatigue. Training should be comprehensive to include all necessary skills and should not assume proficiency on basic skills. Special attention should be focused on managing technical alarms. Increasing the number of super users is a recommended strategy for individualized and unit-specific training. There is a need for a usability testing of complex IT-equipped medical devices, such as physiologic monitors, for effective, efficient and safe navigation of the monitors.

Highlights

  • Clinical alarm systems safety has received immense attention from clinicians, patient safety organizations, and policy makers [1 - 5], especially after the U.S Food and Drug Administration’s (FDA) report indicated 566 alarmrelated patient deaths [5]

  • The majority of nurses were from Neuro (47%) and Surgical Trauma (37%) intensive care units (ICUs)

  • Special attention should be focused on managing technical alarms

Read more

Summary

Introduction

Clinical alarm systems safety has received immense attention from clinicians, patient safety organizations, and policy makers [1 - 5], especially after the U.S Food and Drug Administration’s (FDA) report indicated 566 alarmrelated patient deaths [5]. The Joint Commission (TJC) in the U.S attributed the majority of alarm-related deaths to alarm fatigue and subsequently issued a National Patient Safety Goal (NPSG) on clinical alarm systems safety [1]. In response to Phase II, this study assessed nurses’ perceived competence on physiologic monitors use in intensive care units (ICUs). The majority of studies on alarm systems safety verify the high rate of alarms produced by physiologic monitors, in ICUs [6 - 14] This rate reached 350 alarms per patient per day [3]. In response to Phase II of implementing the National Patient Safety Goal on clinical alarm systems safety, this study assessed nurses’ perceived competence on physiologic monitors use in intensive care units (ICUs) and developed and validated a tool for this purpose

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.