Abstract

The article presents a numerical study of the thermal load on the aquatic environment by using two water discharge pipes under various operational capacities of thermal power plant. It is solved by the Navier-Stokes and temperature transport equations for an incompressible fluid in a stratified medium. The aim of this article is to improve the existing water discharge system for reduce the heat load on the reservoir-cooler of the thermal power plants operation (Ekibastuz SDPP-1). In this article, thermal pollution using only two water discharge pipes, using the existing one and building only one additional in the eastern part of the reservoir-cooler is numerically simulated. The numerical method is based on the projection method, which was approximated by the finite volume method. The obtained numerical results of three-dimensional stratified turbulent flow for two water discharge pipes under various operational capacities of the thermal power plant were compared with experimental data and with the numerical results for one water discharge pipe.