Abstract
A detailed analysis on the characteristics of laminar flow over a bell‐shaped stenosis for a physiological pulsatile flow is presented in this study. In order to have a good understanding of the physiological pulsatile flow, a comparison of the numerical solutions to three types of pulsatile flows, including a physiological flow, an equivalent pulsatile flow and a pure sinusoidal flow, are made in this work. The comparison shows that the flow behavior cannot be properly estimated if the equivalent or simple pulsatile inlet flow is used in the study of flow fields through stenosed arteries instead of actual physiological one. Then the physiological pulsatile flow is further studied by considering the effect of constriction ratio of stenosis, Womersley number and Reynolds number on the flow behavior through stenosed arteries. The analysis shows that the variation of these flow parameters puts significant impacts on the pulsatile flow field for the physiological flow.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Numerical Methods for Heat & Fluid Flow
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.