Abstract

Abstract Orifice flow meters are widely used in industries to measure the flow rate in pipelines. The flow rate inside the pipe can be calculated using the relationship between the flow velocity and the pressure drop across the orifice plate. In the present study, numerical simulations have been carried out using three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations combined with the k-ω SST turbulence model to thoroughly investigate the turbulent flow through a circular square-edged orifice with various orifice plate thicknesses and orifice diameters inside a pipe at different Reynolds numbers ranging from 2500 to 40000. The orifice thickness to pipe diameter ratio (t) varies between 0.125 and 2 and the orifice diameter to pipe diameter (β) varies between 0.25 and 0.75. The resulting centerline profiles of the streamwise velocity and pressure of the present study are compared with the previous published numerical results and experimental data as the validation study. The effects of Reynolds numbers and orifice geometries on the pressure, the flow velocity and vorticity distribution in the orifice are discussed in detail.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.