Abstract
The liquid film thickness seriously affects the distribution of temperature, velocity, and components near the interface for steam condensation in the presence of small concentration noncondensable gas. The liquid film thickness for H2O/CO2 forced convection condensation separation on vertical plate has not been studied numerically. Thus, volume of fluid model and a phase change model were used to study steam condensation in the presence of noncondensable gases. The calculations studied the effects of velocity, surface subcooling, and noncondensable gas mole fraction on the heat transfer for H2O/air or H2O/CO2 mixtures. The results show that the predicted heat transfer coefficients agree well with previous experimental data. The gas and liquid film thicknesses controlling the condensation heat transfer in the presence of a noncondensable gas become thicker as the mixture flows along the cooled wall. The condensate mass flow rate and the heat transfer coefficient are both seriously reduced by the noncondensable gas. The condensate heat transfer in the presence of noncondensable gases is mainly determined by the diffusion coefficient and the thermal conductivities of the components in the gas film layer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.