Abstract
Abstract Post Fukushima, many utilities are planning to install the Filtered Containment Venting System (FCVS) to protect the nuclear reactor containment under severe accident scenarios. FCVS aims at depressurizing the reactor containment and filtering the radioactive gas leaving the containment boundary under such scenarios. A key component of FCVS is the venturi scrubber. The hydrodynamics of the fluid flow inside the FCVS is complex involving multi-phase and multi-component systems with droplets formed by entrainment of high velocity gas stream with liquid jet. The size of droplets and their trajectories are critical with regard to decontamination of iodine which combines with the droplets inside the venturi. Thus, understanding the injection characteristics, hydrodynamics and absorption of iodine vapour with the droplets in the venturi scrubber is very important. There are very limited studies on this aspect. In view of this, a CFD simulation study has been performed in this work for understanding of venturi scrubber operation and performance in self-priming mode. The interaction of the continuous gas phase and droplets is assumed to occur through drag force. The gas flow rate is varied from 1700 to 3400 lpm for two submergence heights of 3 m and 4 m. The liquid loading is estimated from pressure drop at the nozzles observed in the experiments. The retention of iodine in venturi scrubber is calculated assuming instantaneous mass transfer at gas droplet interface. The mass transfer coefficient is evaluated from Steinberg and Treybal correlation. Our results indicate that the liquid loading to the scrubber increases at lower flow rates of 1700 lpm gas flow and further decreases with the increase in gas flow. The two phase pressure profile predicted is close to measured values for each case. The pressure decreases in the converging section; decreases sharply in the throat section due to liquid injection as droplets and shows negligible recovery in the diverging section of the venturi scrubber. The retention of iodine in the venturi scrubber increases with the increase in gas flow rate in the venturi scrubber. This indicates that the participation of venturi scrubber in the iodine retention increases as the air flow rate increases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.