Abstract

The dust removal efficiency of the existing dust control technologies for coal yards involving multiple dust production spots is low and cannot satisfy the requirements stipulated by the existing standards. This paper proposes a new type of vortex blowing suction dust control technology. The principle of dust control was examined through numerical simulations. The dust control efficiency of the single suction and vortex blowing suction methods was compared experimentally. The results indicated that most of the dust particles were collected by the vortex, and they moved in a spiral from the bottom to the top. The highest vortex airflow performance corresponded to an optimal blowing ratio of 4.814. The experimental comparison indicated that the dust removal performance of the vortex blowing suction technique was better. Specifically, for the formal and latter techniques, dust removal efficiency was 93.25% and 41.19%, and dust escape rate was 6.31% and 46.60%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.