Abstract
Computer models are no longer viewed as exotic luxuries, rather they are being increasingly accepted as necessities for effective planning and operation of water distribution systems. In large networks, pressure-reducing valves (PRVs) are common water appurtenances. However, through the use of the Hazen–Williams friction factor, there are difficulties in representing PRVs in network-analysis models. This paper focuses on these difficulties and suggests a procedure for resolving them through the use of modified Hazen–Williams friction factor. The effectiveness of the proposed modification in representing PRVs in the WATER model is demonstrated. Key words: network analysis, numerical modeling, hydraulics, municipal, water distribution, PRV representation, friction coefficient, Hazen–Williams, flow rate, simulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.