Abstract

AbstractIntroducing passive devices in the form of inserts helps to increase the heat transfer characteristics in a circular pipe. In the present work, the feasibility of using two twisted tapes has been numerically studied under laminar flow conditions. Two twisted tapes with configurations of co‐swirl and counter‐swirl conditions were simulated for Re ranging from 1000 to 2500. Heat transfer characteristics like Nusselt number, friction factor, and thermohydraulic performance index (THPI) were investigated. Even the effect of spacing of the tubes inside the pipe was numerically studied. Results indicated that the insertion of two tapes will improve the performance of the circular tube compared with a single tape in terms of a higher Nu and higher THPI. It is observed that for the co‐swirl condition for a Reynolds number of 1000, Nu and THPI is 38% and 29% higher than using a single tape, whereas, for the counter‐swirl condition, they are 43% and 34% higher than that of the single tape condition. Also, it is revealed that counter swirl positioning of the tape with an L/D ratio 0.56 outperformed all other configurations with the highest THPI.