Abstract
The cold flow field in a two dimensional cavity of supersonic combustor has been simulated numerically by using the compressible flow Navier-Stokes equation with the κ-ω SST turbulence model. The flow field structure of different cavity aft wall slope angle (16°,30° and 90°) , different fore aft wall height ratio (1 and 2) and different length depth ratio (3 and 5) are analyzed. The conclusions are as follows: As cavity aft wall slope angle decreases, the compression wave formed at cavity leading separation corner shifts into expansion wave, the shear layer moves into cavity gradually; As cavity fore aft wall height ratio increases from one to two, the expansion wave formed at cavity leading separation corner strengthens and there is no compression wave formed at;As cavity length depth ratio increases from three to five, the compression or expansion wave formed at cavity leading separation corner weakens, cavity bottom wall pressure tends to be constant and aft wall pressure rises.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.