Abstract

An electrified nickel wire can produce heat. The heat is transferred to the environment around the wire radiation. However, the temperature produced by the wire will differ depending on the number of voltages supplied by the power source. Here, we do an experiment to measure the temperature of stand-up wire at each voltage of 4.5 V, 6.0 V, 7.5 V, 9.0 V, and 12 V. As a comparison, numerical measurements are done by JavaScript program. We show that the highest temperature of the wire approaches 314 K at 12 V. To equalize the temperature in both methods, the numerical scale factor of time and current in numerical measurements are changed according to the voltage. As a result, temperatures produced in both methods have minimal gap difference with error percentage below 0.5%. In conclusion, the experiment results were used to determine the scaling parameters to approach the ideal thermal response curve in actual values.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.