Abstract

One of the significant factors that impresses on welded parts’ performance is welding trajectory. Slotted samples with loop and parallel trajectories welded by two steel plates by S235JR and GMAW process. Temperature distributions were registered by the four K type thermocouples. Heat affected zone dimensions were measured on polished and etched cross-sections of each sample. Induced distortions by dial indicators were gauged along welding process and cooling. To evaluate temperature field and distortion in the welding process, three-dimensional FE models were performed. There was good agreement between the FE model predictions and experimental measurements. The most temperatures, distortions and induced longitudinal and transverse residual stresses by welding in the loop trajectory were more than the parallel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.