Abstract

AbstractThe relative humidity is an important parameter reflecting the performance of proton exchange membrane (PEM) fuel cells, which is often accompanied by changes in heat and temperature. In order to study the different humidification effects on the performance of PEM fuel cells, a temperature and heat transfer (T&HT) model is presented. The innovation of this paper is to study the performance of fuel cell (FC) from the perspective of temperature heat transfer by asymmetric humidification. Firstly, symmetrical humidification experiments are performed at three operating temperatures. After that, a three‐dimensional (3D) structure is built using fluent and T&HT model is imported through custom functions. Secondly, the asymmetric humidification experiment is put into practice with 60 °C operating temperature. Furthermore, the Taguchi method is used to optimize the performance of fuel cells in the crossover experiment. Finally, the experimental and numerical results are compared by the contours and polarization curves. The results show that T&HT model is in agreement with the experiment, and asymmetric humidification is more reasonable and flexible than symmetrical humidification. When the cathode relative humidity is 50% and the anode relative humidity is 75%, the maximum optimization rate of system efficiency is 17%.