Abstract

In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the corners and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.