Abstract
In order to investigate Joule heating power, a three-dimensional finite element model (FEM) was developed to predict Joule heating power in the channels of double-loop inductor. The simulated results were compared with experimental data from low load trials for a 400 kW inductor. The results, such as power factor and Joule heating power, show reasonable correlation with experimental data, and Joule heating rate reaches the maximum at the corners and the minimum at the centre of the cross-section area. With increasing relative permeability of iron core, length of coils, current frequency and resistivity of metal melt, the power factor and Joule heating power change. It is concluded that current frequency, the resistivity and length of the coil play a critical role in determining the power factor and Joule heating power, whereas relative permeability of the magnetic core shows no significant influence on them.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.