Abstract
In this paper, the influence of inverter switching harmonics on iron loss and PM loss of Permanent Magnet Synchronous Motor (PMSM) is numerically investigated by Finite Element Method (FEM). In particular, nonlinear FEM is applied for a multi-layered PM Synchronous Motors (PMSMs), Interior buried PMSM (IPMSM) and PM assisted Synchronous Reluctance Motor (PMa-SynRM), which are adoptively designed and compared for Electric Vehicle (EV) propulsion. In particular, iron loss and PM eddy-current loss under the real current waveform including the carrier harmonics from inverter switching are numerically analyzed with nonlinear FEM by considering the skewed stator structure employed for minimizing spatial harmonics.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have