Abstract

The results of a numerical investigation of heat and fluid flow in a liquid cold plate for FM radio power amplifiers are presented. The objective is to verify, by using a commercial CFD code, the performance of a blister cold plate designed to dissipate the heat generated by a known set of electronic components, in order to limit their maximum temperature during operations. Since in a blister cold-plate mainly the cover is thermally active, the cold-plate is simplified and lightened by using plastics in the base plate. A 3-D conjugate CFD approach, where thermal and fluid flow analyses are combined, is followed. Several design options for the cold plate are examined and the validity of the full 3-D CFD approach in the dimensioning of the cooling systems of electronic equipment is demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.