Abstract

In the grid-connected inverter controller system, conventional PI or PR controller decrease their low-frequency gain and bandwidth to maintain the stability of the system. However, this degrades the disturbance rejection and current tracking capability. To solve this problem, this paper gives an H∞ robust control scheme based on Numerator Denominator Model method, which has the advantages of simplified current controller design procedure, can place the poles of closed-loop system at the desired place. By properly selecting the weight function, the proposed control scheme can not only achieve good robustness in disturbance rejection capability, but also gives a straight forward to design the dynamic performance. Simulation and experimental comparison results between PR and H ∞ controller is demonstrated. The results prove that the proposed control scheme shows obviously improvements on the robustness of inverter and meanwhile does not lose advantages on the dynamic performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.