Abstract

ABSTRACT The clogging problem of close-coupled nozzles in the vacuum induction melting gas atomisation (VIGA) process is studied by numerical simulation and industrial experiments. To understand the factors affecting lick back on the nozzle, volume of fluid (VOF) multiphase flow model simulation was adopted to visualise the motion of alloy melt around the outer wall of the delivery tube in the primary atomisation process. When the melt orifice diameter is 4 mm and the atomisation pressure is close to 3.5 MPa, the atomisation process is continuous, the powder particle size is fine, and the atomiser can be reused. When the orifice diameter is 5 mm, and the atomisation pressure is greater than 2.5 MPa, the risk of nozzle clogging is avoided, the powder size is relatively coarse. In the case of using the same atomiser structure, this study explains the mechanism of lick-back and the resulting nozzle damage in VIGA units.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.