Abstract

Microprocessor application in relaying and condition monitoring technology is becoming increasingly popular. In this paper, a novel microprocessor based negative phase sequence (NPS) current detector for motor condition monitoring and relaying for motor/generator protection is developed. The proposed meter eliminates the need of a negative phase sequence filter and does not require complicated digital signal processing techniques. Instead it uses a phase sensitive rectifier. A prototype based on Intel's 8085 A microprocessor was built and tested. Complete circuitry, main and interrupt software flowcharts are provided. Results show the proposed NPS relay and meter can provide a high degree of accuracy and satisfactory results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.