Abstract
Quantitative knowledge of the film thickness and mass fraction of the urea-water solution is very crucial in many practical applications. Film thickness or mass fraction can only be determined individually by conventional measurement techniques. We develop a novel measurement method to measure the film thickness and mass fraction of urea-water solution simultaneously. The absorption coefficients of urea-water solution (5-50 wt%) are measured, a pair of optimized wavelengths is then chosen to achieve high measurement sensitivity. Cross validation is also performed and uncertainties of the technique are smaller than 0.68% for thickness measurements and 1.86% for mass fractions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.