Abstract

We develop a novel method to measure the frequency response of the optoelectronic devices. In this method, an electro-absorption modulator is utilized not only as a modulator but also as a photodetector with the identical frequency response. Based on this property, the frequency responses of the optoelectronic devices can be obtained and the results show good consistency with the measurement results by traditional methods. Instead of using broadband modulators or photodetectors, the frequency response of high bandwidth optoelectronic devices can be measured by using the low bandwidth optoelectronic devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.