Abstract
Background.Among cardiovascular diseases, valve pathology of various aetiology comprises a primary factor of chronic heart failure. Mitral valve diseases afflict over half of all patients with acquired heart defects. Today’s long-term outcomes of mitral valve replacement are not quite satisfactory, which urges the invention of novel vales. Such a modern artificial valve is the nationally developed bivalve full-flow MedInzh-ST prothesis.Objectives.Assessment of advantages of the novel MedInzh-ST full-flow mechanical valve vs. MedInzh-2 model in analyses of short-term postoperative outcomes.Methods. Over a five-year period, 116 patients underwent indicated mitral replacement with MedInzh valves. The full-flow MedInzh-ST was implanted in 55 patients, and MedInzh-2 — in 61. All patients had transthoracic echocardiography for structural and functional heart and implant control prior to surgery and discharge from hospital. Clinical and echocardiographic analyses were performed in the early postoperative period.Results.The choice of valve model had no effect on the rates of postoperative complications and hospital mortality. All lethal cases were not associated with the valve malfunction. All patients with predominant mitral stenosis revealed the reliably lower peak and mean transmitral pressure gradient and pulmonary artery systolic pressure, irrespective of the valve model. The novel full-flow valve implantation significantly more often associated with a reduced right ventricle size. All patients with predominant insufficiency were observed to reduce mitral regurgitation and the left ventricular size upon defect correction. Patients with full-flow protheses significantly more often had a reduced end-systolic dimension.Conclusion.The MedInzh-ST full-flow mechanical valve satisfies the modern requirements for efficacy and safety. Mitral stenosis correction with full-flow valves is shown to exert a greater effect on reverse right ventricular remodelling compared to the classical model.
Highlights
Among cardiovascular diseases, valve pathology of various aetiology comprises a primary factor of chronic heart failure
Clinical and echocardiographic analyses were performed in the early postoperative period
The MedInzh-ST full-flow mechanical valve satisfies the modern requirements for efficacy and safety
Summary
Over a five-year period, 116 patients underwent indicated mitral replacement with MedInzh valves. The full-flow MedInzh-ST was implanted in 55 patients, and MedInzh-2 — in 61. All patients had transthoracic echocardiography for structural and functional heart and implant control prior to surgery and discharge from hospital. Clinical and echocardiographic analyses were performed in the early postoperative period
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.