Abstract
Time-resolved scanning transmission x-ray microscopy (STXM) measurements were performed to study the current-induced magnetization switching mechanism in nanopillars exhibiting strong perpendicular magnetic anisotropy (PMA). This technique provides both short time (70 ps) and high spatial (25 nm) resolution. Direct imaging of the magnetization demonstrates that, after an incubation time of {approx} 1.3 ns, a 100 x 300 nm{sup 2} ellipsoidal device switches in {approx} 1 ns via a central domain nucleation and opposite propagation of two domain walls towards the edges. High domain wall velocities on the order of 100m/s are measured. Micromagnetic simulations are shown to be in good agreement with experimental results and provide insight into magnetization dynamics during the incubation and reversal period.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.